%'px': transform fields from physical coordinates (phys) to image (px) coordinates % OUTPUT: % DataOut: structure of modified data (transforms DataIn) % DataOut.CoordType='px': labels image coordinates % DataOut.CoordUnit= 'px' : units of output coordinates % DataOut.X and .Y arrays of image coordinates X, Y % DataOut.U, .V velocity in pixel displacement on the image (unit=px), if velocity exists as input % %INPUT: % DataIn: structure of possible input data (like UvData) or cell of structures (several fields): % DataIn.CoordType='phys': allows transform to px, else no transform (DataOut=DataIn) % DataIn.X and .Y arrays of physical coordinates X, Y % DataIn.Z corresponding array of Z coordinates (=0 by default) % DataIn.U, V corresponding array of velocity components % DataIn.W corresponding array of the third velocity component in 3D case % DataIn.dt: time interval of the image pair used for velocity measurement (NEEDED TO GET OUTPUT RESULT)) % DataIn.A, AX, AY : image or scalar input -> EMPTY CORRESPONDING OUTPUT (A REVOIR) % Other fields in DataIn: copied to DataOut without modification % Calib: structure containing the calibration parameters (Tsai) or containing a subtree Calib.GeometryCalib with these parameters % % call the functions phys_XYZ or px_XYZ (case of images) for pointwise coordinate transforms function [DataOut,DataOut_1]=px(Data,CalibData,Data_1,CalibData_1)%DataIn,Calib) % A FAIRE: 1- verifier si DataIn est une 'field structure'(.ListVarName'): % chercher ListVarAttribute, for each field (cell of variables): % .CoordType: 'phys' or 'px' (default==px, no transform) % .scale_factor: =dt (to transform displacement into velocity) default=1 % .covariance: 'scalar', 'coord', 'D_i': covariant (like velocity), 'D^i': contravariant (like gradient), 'D^jD_i' (like strain tensor) % (default='coord' if .Role='coord_x,_y..., % 'D_i' if '.Role='vector_x,...', % 'scalar', else (thenno change except scale factor) if ~(exist('CalibData','var') && isfield(CalibData,'GeometryCalib')) DataOut=Data; else DataOut=px_1(Data,CalibData.GeometryCalib); end if exist('Data_1','var') if ~(exist('CalibData_1','var') && isfield(CalibData_1,'GeometryCalib')) DataOut_1=Data_1; else DataOut_1=px_1(Data_1,CalibData_1.GeometryCalib); end else DataOut_1=[]; end %------------------------------------------------ function DataOut=px_1(Data,Calib) DataOut=Data;%default %Act only if .CoordType=phys, and Calib defined if isfield(Data,'CoordType')& isequal(Data.CoordType,'phys')& ~isempty(Calib) DataOut.CoordType='px'; %put flag for pixel coordinates DataOut.CoordUnit='px'; %transform of X,Y coordinates if isfield(Data,'Z')&~isempty(Data.Z) Z=Data.Z; else Z=0; end if isfield(Data,'X') & isfield(Data,'Y') [DataOut.X,DataOut.Y]=px_XYZ(Calib,Data.X,Data.Y,Z); if isfield(Data,'U')&isfield(Data,'V')& isfield(Data,'dt')& ~isequal(Data.dt,0) Data.U=Data.U*Data.dt; Data.V=Data.V*Data.dt; if isfield(Data,'W') W=Data.W*Data.dt; else W=0; end [XOut_1,YOut_1]=px_XYZ(Calib,Data.X-Data.U/2,Data.Y-Data.V/2,Z-W/2); [XOut_2,YOut_2]=px_XYZ(Calib,Data.X+Data.U/2,Data.Y+Data.V/2,Z+W/2); DataOut.U=XOut_2-XOut_1; DataOut.V=YOut_2-YOut_1; end end %transform of an image if isfield(Data,'A')&isfield(Data,'AX')&~isempty(Data.AX) & isfield(Data,'AY')&... isfield(Data,'AY')&~isempty(Data.AY)&length(Data.A)>1 % if isfield(Data,'Field')&isequal(Data.Field,'images') %NO TRANSFORM FROM phys to px for images DataOut.A=[];% end end