Changes between Version 4 and Version 5 of Tutorial/GeometricCalibration
- Timestamp:
- Aug 28, 2013, 10:00:33 AM (11 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
Tutorial/GeometricCalibration
v4 v5 3 3 is 2cm. The corresponding diameter in pixels can be obtained with the ruler displayed by the menu bar '''Tools/ruler''' of uvmat. 4 4 5 First zoom on the cylinder to optimize the precison. Select zoom on, press the left mouse button and adjust the field with the directional key board arrows. Then unselect '''zoom on''' to allowsfor other mouse actions (otherwise zoom has priority). It is also useful to increase the contrast at the cylinder edge by setting '''MaxA''' to 100 in the frame '''Scalar''' (right side of uvmat).5 First zoom on the cylinder to optimize the precison. Select '''zoom on''', press the left mouse button and adjust the field with the directional key board arrows. Then unselect '''zoom on''' to allow for other mouse actions (otherwise zoom has priority). It is also useful to increase the contrast at the cylinder edge by setting '''MaxA''' to 100 in the frame '''Scalar''' (right side of uvmat). 6 6 7 Then select the menu bar the menu bar '''Tools/ruler''', press the left hand mouse button on the cylinder edge, draw a diameter keeping the mouse pressed, release it onthe opposite edge. The length in pixels, 140, is displayed, so the scaling factor is 140/2=70 pixels/cm.7 Then select the menu bar '''Tools/ruler''', press the left hand mouse button on the cylinder edge, draw a diameter keeping the mouse pressed, release it on the opposite edge. The length in pixels, 140, is displayed, so the scaling factor is 140/2=70 pixels/cm. 8 8 9 Open the menu bar '''Tools/geometric calibration'''. A new GUI '''geometry_calib''' appears on the right side. Activate the upper menu bar ''' Tools/Set scale''' on this GUI and introducesthe value 70 in the edit box which pops up, and validate with '''OK'''. A set of calibration point coordinates appears in the table '''[!ListCoord]''' of the GUI.9 Open the menu bar '''Tools/geometric calibration'''. A new GUI '''geometry_calib''' appears on the right side. Activate the upper menu bar '''!Tools/Set scale''' on this GUI and introduce the value 70 in the edit box which pops up, and validate with '''OK'''. A set of calibration point coordinates appears in the table '''[!ListCoord]''' of the GUI. 10 10 11 To see the calibration points , first display the whole image by unselecting fix(tag '''[!CheckFixLimits]''') in the frame '''Coordinates''' of uvmat. Then press '''PLOT PTS''' in '''geometry_calib'''.11 To see the calibration points on the image, first display the whole image by unselecting '''fix''' (tag '''[!CheckFixLimits]''') in the frame '''Coordinates''' of uvmat. Then press '''PLOT PTS''' in '''geometry_calib'''. 12 12