Changes between Version 96 and Version 97 of UvmatHelp
- Timestamp:
- May 10, 2014, 12:39:25 AM (11 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
UvmatHelp
v96 v97 554 554 555 555 ---- 556 == 8 - Geometric calibration == 556 == 8 - Geometric calibration == #GeometryCalib 557 557 === 8.1 Generalities === 558 558 Transforming image to physical coordinates is a prerequisit for measuring techniques based on imaging. … … 656 656 657 657 ---- 658 == 10 - Processing field series == 658 == 10 - Processing field series == #Series 659 659 === 10.1 The GUI series.fig === 660 660 Operations on field series are controled by the GUI '''series.fig''', which allows the user to set the root name(s) and file indices over which a processing function operates. The GUI can be opened from '''uvmat''' through its menu bar option '''[Run/series]'''. It then mirrors the settings of '''uvmat'''. It can be alternatively opened by typing the Matlab command ''>>series'', then selecting the input file series by the menu bar command '''[Open]'''. … … 716 716 717 717 ---- 718 == 11 - PIV: Particle Imaging Velocimetry == 718 == 11 - PIV: Particle Imaging Velocimetry == #Civ 719 719 === 11.1 Overview === 720 720 PIV can be performed by selecting the Matlab function ''civ_series'' as '''[!ActionName]''' in the GUI '''series.fig''': then the '''GUI civ_input''' appears to enter the processing parameters. An image file series must have been entered as input of '''series.fig''', or alternatively a Netcdf file resulting form a previous PIV processing (with conventions 'civdata').