    117117'''Particle Imaging Velocimetry (PIV)'''
    118 A xxxx laser in conjunction with 3 cameras was used to provide PIV images. The laser light sheet was brought in parallel to the floor of the channel. The light sheet can then be racked in the vertical through a series of steps through the use of a motorized mirror, and synchronized with the PIV cameras. The field of view extends from close to the upstream end of the first bend, towards the mid-point of the second bend.
    119 
     118A Spectra-Physics xxxx laser in conjunction with 3 cameras was used to provide PIV images. The laser light sheet was brought in parallel to the floor of the channel. The light sheet can then be racked in the vertical through a series of steps through the use of a motorized traverse and a mirror; the laser is pointed down at the mirror producing the light sheet. The laser light sheet positions are then synchronized with the PIV cameras. The field of view extends from close to the upstream end of the first bend, towards the mid-point of the second bend.
    120119
    121120== 3.2 Definition of time origin and instrument synchronisation ==