Changes between Version 34 and Version 35 of WikiStart
- Timestamp:
- Sep 13, 2017, 10:18:13 AM (9 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
WikiStart
v34 v35 16 16 ||||||||$(m)$||$(s)$||$(L min!^{-1})$||$(m)$||$(kg m!^{-3}$||$(mm)$||$H_1,H_2,\Delta t $||VS/HS/Scan||$cm$||$cm$||t1/t2/t3[[BR]]$\Delta t$||yes / no|||||| 17 17 ||0||test||11092017 __[https://servforge.legi.grenoble-inp.fr/projects/pj-coriolis-17iceshelf/search?q=hh%3Amm hh:mm]__||0.604||50||58.5||0.50||0||13||170,150,41s||VS||-||-||?||yes||Dye did not show up in photos :-(||Elin|| 18 ||1||exp01||12092017[[BR]]!14:38||0.584||50||40.67||0.50||0||12.6||170,150,59s||HS,VS,Scan||55||55:[-5:30,[[BR]]4 -5:30, 4]||500ms[[BR]](reality: 1000ms)||no||Expl. time = 50 ms too little. Only every second photo was taken||Nadine|| 19 ||2||exp02||12092017[[BR]]!17:02||0.583||50||44.2||0.50||0||12.6||180,150,81.4s||HS||55?||-||200ms[[BR]](reality: 400ms)||no||Only every second photo was taken||Nadine|| 18 ||1||exp01||12092017[[BR]]!14:38||0.584||50||40.67||0.50||0||12.6||170,150,59s||HS,VS,Scan||55||55:-5:30,4||500ms[[BR]](reality: 1000ms)||no||Expl. time = 50 ms too little. Only every second photo was taken||Elin|| 19 ||2||exp02||12092017[[BR]]!17:02||0.583||50||44.2||0.50||0||12.6||180,150,81.4s||HS||55?||-||200ms[[BR]](reality: 400ms)||no||Only every second photo was taken||Elin|| 20 ||3||exp03||13092017||||50||||0.50||0||12.6||||HS,Scan||||||200ms||no||Problem with photos fixed; particles in ambient||Elin|| 20 21 21 22 = = … … 229 230 '''Test experiment EXP01''' 230 231 231 We conducted experiments with a long HS from the beginning after turning on the influx (EXP_01). The influx was 40.67 L/min with a diaphragma of 12.6 mm diameter. The influx water had a density of 998.2 and was enriched with particles of size 30 ('''unit???'''). The laser sheet was at 11cm over the trough, 4 cm over the shelf, so at 54 cm when the laser setting was at 650. We decreased it to 640 to have the laser sheet at 55 cm. Water level was at 58.4 cm. The exposure time of the cameras was at 50ms ('''???''') and the time interval 500 ms. 232 We conducted experiments with a long HS from the beginning after turning on the influx (EXP_01). The influx was 40.67 L/min with a diaphragma of 12.6 mm diameter. The influx water had a density of 998.2 and was enriched with particles of size 30 ('''unit???'''). The laser sheet was at 11cm over the trough, 4 cm over the shelf, so at 54 cm when the laser setting was at 650. We decreased it to 640 to have the laser sheet at 55 cm. Water level was at 58.4 cm. The exposure time of the cameras was at 50ms ('''???''') and the time interval 500 ms. 232 233 233 234 Now we switched to the VS at 14:58 (EXP01_VERT). ('''Do we know anything about the setting there?''')
